8:00430.33376.79385.1428.21276.81262.11
9:00523.65529.9535.2516.42463.7416.04
10:00550.44575.5576549.67473.7424.13
11:00550.70574.41577.8548.48457.1407.47
12:00545.32538.19541.99543.32432.7396.01
13:00535.00519.7521.21542.12440.8397.46
14:00545.77557.11559546.78446.09403.2
15:00533.72524529.89534.14409.31369.8
16:00538.55550.3551.2537.81460.9411.7
17:00547.60562.39562.91540.41474.59426.1
18:00551.27520.7520.2544.38505.2448
19:00548.49468.8466.89549.74500.41445.5
20:00545.82463.1464.51550.53507453.29
21:00526.76428.7436.9527.04427.5385.51
22:00521.87422.8431.1521.74505.59451.29
23:00428.33325.01338.09432.99306.5290.21
0:00381.94292.1308.11380.45229.21223.5
平均469.94428.36436.03468.74363.71332.86
#1、2炉对比两台送风机日平均节电23%。
5存在的问题
5.1在进行高低速改造后,风机试转过程中A、B送风机均出现高速运行电机堵转动作跳闸情况,主要为电机接线方式发生改变后启动电流返回时间延长,现已将堵转保护时限由3S调至8S。
5.2送风机降速运行后由于其动叶开度较改造前增大,所以在变负荷过程中其动态响应PID参数需要适当调整,此外一台风机跳闸后运行风机超持指令也需相应增加,否者易造成低氧或缺氧燃烧。
5.3送风机降速运行后夏季满负荷运行时风机出力接近上限,若动叶开度在检修过程中不能够及时准确校对,则会严重制约风机出力。我厂在实施改造后1B送风机相同出力下动叶开度一直偏大8%左右,动叶开度达上限后严重制约的送风量的调整。
5.4由于我厂属于煤电联营电厂,煤质稳定,基本上接近校核煤种。送风机降速运行后,针对夏季满负荷运行且煤质严重偏离设计值的机组,降速改造需谨慎。
6结束语
虽然高低速改造节能效果与运行调整灵活性不及变频改造,但高低速运行具有变频运行不可比拟的安全可靠性,具投资少回收快的节能效果,值得推广。