³ôÑõµÄ²úÁ¿Ò²Í¨¹ýÈ˹¤²»¶ÏµØµ÷½Ú£¬Ö±µ½µ½´ï×îС³ôÑõ¼ÁÁ¿(3g O₃/m3ÎÛË®)£¬´ËºóÈÃËü°´´ËËÙÂÊÔËÐÐ4¸öHRTµÄʱ¼ä(20·ÖÖÓ)£¬È»ºó²Å¿ªÊ¼²ÉÑù¡£²ÉÑù·½Ê½ÊÇÔÚ1СʱÄÚÔÚIN¡¢AFºÍOUTÈý¸öµãÿ10·ÖÖÓ²ÉÒ»´Î²ÉÑùÁ¿·Ö±ðΪ0.5L¡¢0.5LºÍ1.5L£¬ËùÒÔÒ»¹²ÓÐÈý¸öµãµÄ²ÉÑùÁ¿·Ö±ðÓÐ3.5L¡¢3.5LºÍ10.5L¡£È»ºó·Ö±ðÒÔ5gO3/m3ÎÛË®ºÍ7g O₃/m3ÎÛË®µÄ³ôÑõ¼ÁÁ¿Öظ´ÊÔÑé¡£INºÍAFµÄÑùÆ·×÷ΪÕû¸öÊÔÑéµÄ»ìºÏÑù¡£
ÑùÆ·ËÍÖÁ¡µÂ´óѧʵÑéÊÒ½øÐзÖÎö£¬¼ì²âÏî°üÀ¨COD¡¢TOC¡¢PO4-P¡¢TN¡¢NH4-N¡¢NO3-N¡¢NO2-NºÍSSºÍpH¡£Ò©Îï·ÖÎöÔòÓÐÈðµä»·¾³Ñо¿ÔºIVL½øÐС£
±í2. ¶þÊ®ËÄÖÖÒ©ÎïÃûµ¥
ʵÑé½á¹û
ÓÉÓÚÅ·ÃËĿǰûÓжÔÌض¨Ò©ÎïµÄÅÅ·ÅŨ¶È±ê×¼£¬Òò´ËÕâ¸öʵÑéµÄÒ©ÎïÈ¥³ýÇé¿öÓÉËùÓзÖÎöµÄÒ©ÎïŨ¶È¼õÉÙÂÊÀ´±íʾ£¬²¢ÓÃÈðÊ¿µÄ80%È¥³ýÂÊ×÷Ϊ²ÎÕÕ¡£
Ò©ÎïŨ¶ÈµÄ¼ì²â½á¹ûÏÔʾ(ϱí3)£¬Ò©ÎïµÄ×ÜŨ¶È·¶Î§ÔÚ4600-18700 ng/L¡£ÈýÖÖ²»Í¬µÄ³ôÑõ¼ÁÁ¿ÏµÄƽ¾ùÈ¥³ýÂÊ(ͼ4)·Ö±ðλ65%(3g O₃/m3)¡¢78%(5g O₃/m3)¡¢88%(7g O₃/m3)¡£ÁíÍâÄÜ¿´µ½£¬ÎÛË®³§µÄ´ï±êÊýÁ¿Óë³ôÑõ¼ÁÁ¿³ÊÕýÏà¹Ø¡£
±í3. ϵͳ³öÈë¿ÚµÄÒ©ÎïŨ¶È½á¹û
ͼ4 ÔÚ²»Í¬³ôÑõ¼ÁÁ¿ÏµÄÈ¥³ýÂʶԱÈ
Ñо¿ÈËÔ±Ëæºó¸ù¾ÝÈ¥³ýÂʽ«24ÖÖÒ©Îï½øÐзÖ×飬ÕÒ³ö¸÷Ò©ÎïµÄ´ï±êÇé¿ö¡£Ç°Á½×éµÄÒ©Îï¸úAntoniouµÈÈË(2013)ºÍMargot µÈÈË(2013)µÄÑо¿½á¹ûÎǺϡ£ºóÁ½×éµÄÒ©Îï¸úHey µÈÈË(2014)ºÍHollender µÈÈË(2009)µÄÑо¿½á¹ûÎǺϡ£
±í4. ¸ù¾ÝÈ¥³ýÂʵÄÒ©Îï·Ö×é
ͼ5. µ¥¸öÒ©ÎïÔÚ²»Í¬³ôÑõ¼ÁÁ¿µÄÈ¥³ýÂʶԱÈ
ÉÏͼ5ÏÔʾһЩҩÎïµÄÈ¥³ýÂʵıê×¼²î½Ï´ó£¬ÓÈÆäÔÚ×îµÍµÄ³ôÑõ¼ÁÁ¿µÄÇé¿öÏ£¬ÀýÈç²¼Âå·Ò¡£ÊµÑéÍŶÓÎÞ·¨¶Ô´Ë¸ø³öÈ·ÇнâÊÍ£¬µ«ÈÏΪÖÐÊÔ¹æÄ£ºÍ½øˮˮÖʵı仯¶¼ÊÇ¿ÉÄܵijÉÒò¡£ÁíÍâÊý¾ÝÒ²ÏÔʾÈç¹ûÒ»ÖÖÎïÖÊÔ½Äѷֽ⣬ÄÇôȥ³ýÂʵı仯ÔòÔ½´ó¡£
ÓÃTOC´î½¨³ôÑõ¼ÁÁ¿Ä£ÐÍ?
TOCºÍÒ©ÎïÈ¥³ýÂʵĹØϵÈçÏÂͼ6Ëùʾ¡£ËäÈ»ÎÒÃÇ¿ÉÒÔ¿´µ½³ôÑõ¼ÁÁ¿ÓëTOCÕûÌå³ÊÕýÏà¹Ø£¬µ«¸ù¾ÝÕâ´ÎÊÔÑéµÄÀëÉ¢µãºÜÄÑÄâºÏ³öÒ»Ìõ׼ȷµÄ»Ø¹éÇúÏß¡£ËùÒÔÕâ´Î½¨Ä£µÄ³¢ÊÔ¿ÉÒÔ˵ÊÇÒÔʧ°Ü¸æÖÕ¡£
ͼ6.µ¥Î»³ôÑõ¼ÁÁ¿ºÍÒ©ÎïÈ¥³ýÂʵĽáºÏÇúÏß
ÓÉÓÚSvedalaºÍVästra StrandenÎÛË®³§µÄÈ¥³ýÂÊÌرðµÄµÍ£¬Ö®ºó¶ÔÆä½øÐжîÍâ·ÖÎö£ºSvedala½øË®µÄÒ©ÎïŨ¶È×î¸ß£¬´ï18702 ng/L£¬µ«ÆäʵÓëEllingeÎÛË®³§µÄ17860 ng/L²î¾à²»´ó¡£¶øVästra StrandenµÄÇé¿ö(7838 ng/L)ÔòÓëNyvångsverket½Ó½ü(8359 ng/L)¡£Òò´ËÅųýÁ˽øˮŨ¶ÈµÄÔÒò¡£ËûÃÇ»¹ÒâÍâ·¢ÏÖ³ôÑõ»¹»áÑõ»¯ÑÇÏõ̬µª£¬¶øΨ¶ÀSvedalaºÍVästra StrandenÎÛË®³§µÄÑÇÏõ̬µªÃ»Óб»Ñõ»¯¡£µ«ºóÀ´ËûÃÇÓÖ·¢ÏÖÁ½×ùÎÛË®³§µÄ½øË®ÑÇÏõ̬µªÅ¨¶È±¾À´¾ÍºÜµÍ£¬ËùÒÔÕâ¸öÔÒòÒ²ÅųýÁË¡£ËûÃDz²â¿ÉÄÜÊÇÓÐδ֪µÄÎïÖÊÏûºÄÁ˳ôÑõ£¬µ«ÎÞ·¨¼ì²â³öÀ´¡£
½áÂÛ
ͨ¹ýÕâ´ÎÖÐÊÔ£¬Ñо¿ÈËÔ±·¢ÏÖ³ôÑõ´¦Àí¶Ô´ó²¿·ÖÎÛË®³§µÄÒ©ÎïÈ¥³ýÊÇÓÐЧµÄ£¬¶øÇÒËûÃǼø¶¨³öÁËÒ»¸ö³õ²½µÄ³ôÑõŨ¶È¡ª¡ª7g O₃/m3¡£Õâ·Ý±¨¸æÀïûÓжԳɱ¾½øÐоßÌå¼ÆË㣬ֻ¸ø³öÁËMulderµÈÈËÔÚ2015ÄêµÄÑо¿±¨¸æÀïµÄ²Î¿¼³É±¾£º7.7g O₃/m3µÄ¼ÁÁ¿¶ÔÓ¦0.16€/m3ÎÛË®(300000ÈË¿Úµ±Á¿µÄÎÛË®³§)£¬Ê¹ÓÿÅÁ£»îÐÔÌ¿µÄ³É±¾Ï൱£¬Îª0.18€/m3ÎÛË®¡£
Òź¶µÄÊÇSvedala ºÍVästra StrandenÁ½¸öÎÛË®³§µÄÈ¥³ýЧ¹ûÒì³££¬µ«ÎÞ·¨¶Ô´Ë¸ø³öºÏÀíµÄ³ÉÒò½âÊÍ¡£
ÁíÍâËûÃÇ·¢ÏÖµ¥Î»³ôÑõ¼ÁÁ¿(O₃ºÍTOCµÄ±ÈÖµ)ÓëÒ©ÎïÈ¥³ýÂÊÖ®¼ä´æÔÚÏà¹ØÐÔ£¬µ«ÒòΪËü²»¹»¾«È·£¬Òò´Ë²»×ãÒÔ×÷Ϊ¿ØÖƳôÑõÊä³öµÄ²ÎÊý¡£Òò´ËÈç¹ûÏ뽨Á¢Ò»¸öÆÕ±éʹÓÃÓÚÈκÎÎÛË®´¦Àí³§µÄ³ôÑõ¼ÁÁ¿Ä£ÐÍ£¬ËûÃÇ»¹ÐèÒªºÜ¶à¹¤×÷Òª×ö¡£
ÑÓÉìÔĶÁ£º
µÂ¹úÂüº£Ä·ÎÛË®´¦Àí³§£º·ÛÄ©»îÐÔÌ¿È¥³ý΢Á¿ÎÛȾÎï
µÍѹĤ·ÖÀë¼¼ÊõÈçºÎ´¦Àí¾»Ë®ÖеÄ΢Á¿ÓлúÎÛȾÎï
»·±£¼¼ÊõÈËԱѧϰ³É³¤½»Á÷Ⱥ
־ͬµÀºÏµÄС»ï°éÈ«ÔÚÕâÀï
ÌرðÉùÃ÷£º±±¼«ÐÇתÔØÆäËûÍøÕ¾ÄÚÈÝ£¬³öÓÚ´«µÝ¸ü¶àÐÅÏ¢¶ø·ÇÓ¯Àû֮ĿµÄ£¬Í¬Ê±²¢²»´ú±íÔÞ³ÉÆä¹Ûµã»ò֤ʵÆäÃèÊö£¬ÄÚÈݽö¹©²Î¿¼¡£°æȨ¹éÔ×÷ÕßËùÓУ¬ÈôÓÐÇÖȨ£¬ÇëÁªÏµÎÒÃÇɾ³ý¡£
·²À´Ô´×¢Ã÷±±¼«ÐÇ*ÍøµÄÄÚÈÝΪ±±¼«ÐÇÔ´´£¬×ªÔØÐè»ñÊÚȨ¡£
°æȨËùÓÐ © 1999-2022 ±±¼«ÐÇ»·±£Íø ÔËÓª£º±±¾©»ðɽ¶¯Á¦ÍøÂç¼¼ÊõÓÐÏÞ¹«Ë¾ ¹ã¸æ×Ü´úÀí£º±±¾©å«Åôʱ´ú¿Æ¼¼·¢Õ¹ÓÐÏÞ¹«Ë¾
¾©ICPÖ¤080169ºÅ¾©ICP±¸09003304ºÅ-2¾©¹«Íø°²±¸11010502034458ºÅµç×Ó¹«¸æ·þÎñרÏ°¸
ÍøÂçÎÄ»¯¾ÓªÐí¿ÉÖ¤ [2019] 5229-579ºÅ¹ã²¥µçÊÓ½ÚÄ¿ÖÆ×÷¾ÓªÐí¿ÉÖ¤ (¾©) ×ÖµÚ13229ºÅ³ö°æÎï¾ÓªÐí¿É֤гö·¢¾©Åú×ÖµÚÖ±200384ºÅÈËÁ¦×ÊÔ´·þÎñÐí¿ÉÖ¤1101052014340ºÅ
Copyright ? 2022 Bjx.com.cn All Rights Reserved. ±±¾©»ðɽ¶¯Á¦ÍøÂç¼¼ÊõÓÐÏÞ¹«Ë¾ °æȨËùÓÐ