»·±£ÐÐÒµ´¹Ö±ÃÅ»§ÍøÕ¾

ÐÂÎÅ
  • ÐÂÎÅ
  • ²úÆ·
  • ÆóÒµ
µ±Ç°Î»Ö㺻·±£ > ¼¼Êõ > ÕýÎÄ

´ÓÈðµä10×ùÎÛË®³§°¸Àý¿´ÎÛË®ÖÐÐÂÐËÎÛȾÎïµÄÈ¥³ý

±±¼«ÐÇ»·±£ÍøÀ´Ô´:¸øË®ÅÅË®2018/8/31 9:00:59ÎÒҪͶ¸å
ËùÊôÐÐÒµ: Ë®´¦Àí  ¹Ø¼ü´Ê£ºÎÛË®³§ Éú»îÎÛË® ÎÛË®´¦Àí

³ôÑõµÄ²úÁ¿Ò²Í¨¹ýÈ˹¤²»¶ÏµØµ÷½Ú£¬Ö±µ½µ½´ï×îС³ôÑõ¼ÁÁ¿(3g O₃/m3ÎÛË®)£¬´ËºóÈÃËü°´´ËËÙÂÊÔËÐÐ4¸öHRTµÄʱ¼ä(20·ÖÖÓ)£¬È»ºó²Å¿ªÊ¼²ÉÑù¡£²ÉÑù·½Ê½ÊÇÔÚ1СʱÄÚÔÚIN¡¢AFºÍOUTÈý¸öµãÿ10·ÖÖÓ²ÉÒ»´Î²ÉÑùÁ¿·Ö±ðΪ0.5L¡¢0.5LºÍ1.5L£¬ËùÒÔÒ»¹²ÓÐÈý¸öµãµÄ²ÉÑùÁ¿·Ö±ðÓÐ3.5L¡¢3.5LºÍ10.5L¡£È»ºó·Ö±ðÒÔ5gO3/m3ÎÛË®ºÍ7g O₃/m3ÎÛË®µÄ³ôÑõ¼ÁÁ¿Öظ´ÊÔÑé¡£INºÍAFµÄÑùÆ·×÷ΪÕû¸öÊÔÑéµÄ»ìºÏÑù¡£

ÑùÆ·ËÍÖÁ¡µÂ´óѧʵÑéÊÒ½øÐзÖÎö£¬¼ì²âÏî°üÀ¨COD¡¢TOC¡¢PO4-P¡¢TN¡¢NH4-N¡¢NO3-N¡¢NO2-NºÍSSºÍpH¡£Ò©Îï·ÖÎöÔòÓÐÈðµä»·¾³Ñо¿ÔºIVL½øÐС£

±í2. ¶þÊ®ËÄÖÖÒ©ÎïÃûµ¥

ʵÑé½á¹û

ÓÉÓÚÅ·ÃËĿǰûÓжÔÌØ¶¨Ò©ÎïµÄÅÅ·ÅŨ¶È±ê×¼£¬Òò´ËÕâ¸öʵÑéµÄÒ©ÎïÈ¥³ýÇé¿öÓÉËùÓзÖÎöµÄÒ©ÎïŨ¶È¼õÉÙÂÊÀ´±íʾ£¬²¢ÓÃÈðÊ¿µÄ80%È¥³ýÂÊ×÷Ϊ²ÎÕÕ¡£

Ò©ÎïŨ¶ÈµÄ¼ì²â½á¹ûÏÔʾ(ϱí3)£¬Ò©ÎïµÄ×ÜŨ¶È·¶Î§ÔÚ4600-18700 ng/L¡£ÈýÖÖ²»Í¬µÄ³ôÑõ¼ÁÁ¿ÏÂµÄÆ½¾ùÈ¥³ýÂÊ(ͼ4)·Ö±ðλ65%(3g O₃/m3)¡¢78%(5g O₃/m3)¡¢88%(7g O₃/m3)¡£ÁíÍâÄÜ¿´µ½£¬ÎÛË®³§µÄ´ï±êÊýÁ¿Óë³ôÑõ¼ÁÁ¿³ÊÕýÏà¹Ø¡£

±í3. ϵͳ³öÈë¿ÚµÄÒ©ÎïŨ¶È½á¹û

ͼ4 ÔÚ²»Í¬³ôÑõ¼ÁÁ¿ÏµÄÈ¥³ýÂʶԱÈ

Ñо¿ÈËÔ±Ëæºó¸ù¾ÝÈ¥³ýÂʽ«24ÖÖÒ©Îï½øÐзÖ×飬ÕÒ³ö¸÷Ò©ÎïµÄ´ï±êÇé¿ö¡£Ç°Á½×éµÄÒ©Îï¸úAntoniouµÈÈË(2013)ºÍMargot µÈÈË(2013)µÄÑо¿½á¹ûÎǺϡ£ºóÁ½×éµÄÒ©Îï¸úHey µÈÈË(2014)ºÍHollender µÈÈË(2009)µÄÑо¿½á¹ûÎǺϡ£

±í4. ¸ù¾ÝÈ¥³ýÂʵÄÒ©Îï·Ö×é

ͼ5. µ¥¸öÒ©ÎïÔÚ²»Í¬³ôÑõ¼ÁÁ¿µÄÈ¥³ýÂʶԱÈ

ÉÏͼ5ÏÔʾһЩҩÎïµÄÈ¥³ýÂʵıê×¼²î½Ï´ó£¬ÓÈÆäÔÚ×îµÍµÄ³ôÑõ¼ÁÁ¿µÄÇé¿öÏ£¬ÀýÈç²¼Âå·Ò¡£ÊµÑéÍŶÓÎÞ·¨¶Ô´Ë¸ø³öÈ·ÇнâÊÍ£¬µ«ÈÏΪÖÐÊÔ¹æÄ£ºÍ½øË®Ë®Öʵı仯¶¼ÊÇ¿ÉÄܵijÉÒò¡£ÁíÍâÊý¾ÝÒ²ÏÔʾÈç¹ûÒ»ÖÖÎïÖÊÔ½Äѷֽ⣬ÄÇôȥ³ýÂʵı仯ÔòÔ½´ó¡£

ÓÃTOC´î½¨³ôÑõ¼ÁÁ¿Ä£ÐÍ?

TOCºÍÒ©ÎïÈ¥³ýÂʵĹØÏµÈçÏÂͼ6Ëùʾ¡£ËäÈ»ÎÒÃÇ¿ÉÒÔ¿´µ½³ôÑõ¼ÁÁ¿ÓëTOCÕûÌå³ÊÕýÏà¹Ø£¬µ«¸ù¾ÝÕâ´ÎÊÔÑéµÄÀëÉ¢µãºÜÄÑÄâºÏ³öÒ»Ìõ׼ȷµÄ»Ø¹éÇúÏß¡£ËùÒÔÕâ´Î½¨Ä£µÄ³¢ÊÔ¿ÉÒÔ˵ÊÇÒÔʧ°Ü¸æÖÕ¡£

ͼ6.µ¥Î»³ôÑõ¼ÁÁ¿ºÍÒ©ÎïÈ¥³ýÂʵĽáºÏÇúÏß

ÓÉÓÚSvedalaºÍVästra StrandenÎÛË®³§µÄÈ¥³ýÂÊÌØ±ðµÄµÍ£¬Ö®ºó¶ÔÆä½øÐжîÍâ·ÖÎö£ºSvedala½øË®µÄÒ©ÎïŨ¶È×î¸ß£¬´ï18702 ng/L£¬µ«ÆäʵÓëEllingeÎÛË®³§µÄ17860 ng/L²î¾à²»´ó¡£¶øVästra StrandenµÄÇé¿ö(7838 ng/L)ÔòÓëNyvångsverket½Ó½ü(8359 ng/L)¡£Òò´ËÅųýÁ˽øË®Å¨¶ÈµÄÔ­Òò¡£ËûÃÇ»¹ÒâÍâ·¢ÏÖ³ôÑõ»¹»áÑõ»¯ÑÇÏõ̬µª£¬¶øÎ¨¶ÀSvedalaºÍVästra StrandenÎÛË®³§µÄÑÇÏõ̬µªÃ»Óб»Ñõ»¯¡£µ«ºóÀ´ËûÃÇÓÖ·¢ÏÖÁ½×ùÎÛË®³§µÄ½øË®ÑÇÏõ̬µªÅ¨¶È±¾À´¾ÍºÜµÍ£¬ËùÒÔÕâ¸öÔ­ÒòÒ²ÅųýÁË¡£ËûÃDz²â¿ÉÄÜÊÇÓÐδ֪µÄÎïÖÊÏûºÄÁ˳ôÑõ£¬µ«ÎÞ·¨¼ì²â³öÀ´¡£

½áÂÛ

ͨ¹ýÕâ´ÎÖÐÊÔ£¬Ñо¿ÈËÔ±·¢ÏÖ³ôÑõ´¦Àí¶Ô´ó²¿·ÖÎÛË®³§µÄÒ©ÎïÈ¥³ýÊÇÓÐЧµÄ£¬¶øÇÒËûÃǼø¶¨³öÁËÒ»¸ö³õ²½µÄ³ôÑõŨ¶È¡ª¡ª7g O₃/m3¡£Õâ·Ý±¨¸æÀïûÓжԳɱ¾½øÐоßÌ弯Ë㣬ֻ¸ø³öÁËMulderµÈÈËÔÚ2015ÄêµÄÑо¿±¨¸æÀïµÄ²Î¿¼³É±¾£º7.7g O₃/m3µÄ¼ÁÁ¿¶ÔÓ¦0.16€/m3ÎÛË®(300000È˿ڵ±Á¿µÄÎÛË®³§)£¬Ê¹ÓÿÅÁ£»îÐÔÌ¿µÄ³É±¾Ï൱£¬Îª0.18€/m3ÎÛË®¡£

Òź¶µÄÊÇSvedala ºÍVästra StrandenÁ½¸öÎÛË®³§µÄÈ¥³ýЧ¹ûÒì³££¬µ«ÎÞ·¨¶Ô´Ë¸ø³öºÏÀíµÄ³ÉÒò½âÊÍ¡£

ÁíÍâËûÃÇ·¢ÏÖµ¥Î»³ôÑõ¼ÁÁ¿(O₃ºÍTOCµÄ±ÈÖµ)ÓëÒ©ÎïÈ¥³ýÂÊÖ®¼ä´æÔÚÏà¹ØÐÔ£¬µ«ÒòΪËü²»¹»¾«È·£¬Òò´Ë²»×ãÒÔ×÷Ϊ¿ØÖƳôÑõÊä³öµÄ²ÎÊý¡£Òò´ËÈç¹ûÏ뽨Á¢Ò»¸öÆÕ±éʹÓÃÓÚÈκÎÎÛË®´¦Àí³§µÄ³ôÑõ¼ÁÁ¿Ä£ÐÍ£¬ËûÃÇ»¹ÐèÒªºÜ¶à¹¤×÷Òª×ö¡£

ÑÓÉìÔĶÁ£º

µÂ¹úÂüº£Ä·ÎÛË®´¦Àí³§£º·ÛÄ©»îÐÔ̿ȥ³ý΢Á¿ÎÛȾÎï

µÍѹĤ·ÖÀë¼¼ÊõÈçºÎ´¦Àí¾»Ë®ÖеÄ΢Á¿ÓлúÎÛȾÎï

³ÇÕòÎÛË®´¦Àí³§ÎÛȾÎïÅŷűê×¼GB18918-2002

ÎÛË®´¦ÀíÖÐÖÐ20¶àÖÖ³£¼ûÎÛȾÎïÀ´Ô´¼°´¦Àí·½·¨

»·±£¼¼ÊõÈËԱѧϰ³É³¤½»Á÷Ⱥ
־ͬµÀºÏµÄС»ï°éÈ«ÔÚÕâÀï

Ͷ¸åÁªÏµ£º0335-3030550  
ÓÊÏ䣺huanbaowang#bjxmail.com£¨Ç뽫#»»³É@£©

ÌØ±ðÉùÃ÷£º±±¼«ÐÇ×ªÔØÆäËûÍøÕ¾ÄÚÈÝ£¬³öÓÚ´«µÝ¸ü¶àÐÅÏ¢¶ø·ÇÓ¯Àû֮ĿµÄ£¬Í¬Ê±²¢²»´ú±íÔÞ³ÉÆä¹Ûµã»ò֤ʵÆäÃèÊö£¬ÄÚÈݽö¹©²Î¿¼¡£°æÈ¨¹éÔ­×÷ÕßËùÓУ¬ÈôÓÐÇÖȨ£¬ÇëÁªÏµÎÒÃÇɾ³ý¡£

·²À´Ô´×¢Ã÷±±¼«ÐÇ*ÍøµÄÄÚÈÝΪ±±¼«ÐÇÔ­´´£¬×ªÔØÐè»ñÊÚȨ¡£

ÍÆ¼öÔĶÁ

MBBR¹¤ÒÕ¹¤×÷Ô­Àí¼°Ó¦ÓÃÌØµã
±¾ÎÄÖ÷Òª½éÉÜÁËÒÆ¶¯´²ÉúÎïĤ¹¤ÒյĵŤ×÷Ô­Àí£¬Ì½
»ðµç³§ÍÑÁò·ÏË®ÁãÅŷż¼Êõ·ÖÎö
¹úÎñÔº·¢²¼¡°Ë®Ê®Ìõ¡±ÒÔÀ´£¬¹ú¼Ò½«Ç¿»¯¶Ô¸÷ÀàË®ÎÛ
¼¸ÖÖÀ¬»ø·ÙÉÕ¯ÅŵĽéÉÜ
ÖÚËùÖÜÖª£¬Â¯ÅÅϵͳÊǯÅÅʽÀ¬»ø·ÙÉÕ¯ÖÐ×îºËÐĵÄ
Èí»¯Ê÷֪֬ʶµãÏêϸ½²½â
Ë®´¦ÀíÊ÷Ö¬·ÖΪÑôÀë×ÓÊ÷Ö¬ºÍÒõÀë×ÓÊ÷Ö¬,ÑôÀë×ÓÊ÷
Ñ̵ÀÉè¼ÆÅàѵ×ÊÁÏ
»ðÁ¦·¢µç³§£¬Ñ̵ÀÉè¼ÆÅàѵ£¬´ÓÆß¸ö·½Ãæ½éÉÜÁËÑÌÆø

»·±£¼¼ÊõÈȶȰñ

±¾ÖÜÅÅÐÐ
±¾ÔÂÅÅÐÐ
  1. ÖÇÄܵç±íÖеķ塢¼â¡¢Æ½¡¢¹ÈÊÇʲôÒâ˼£¿ÔõôËãµç·Ñ£¿
  2. »¯¹¤ÆóÒµµÍѹµç¶¯»úÈçºÎ·À¡°»Îµç¡±£¿ÉîÛÚÖе翹»Îµç×°Öýâ¾ö·½°¸
  3. ½­Î÷ÍêÉÆ·Öʱµç¼Û»úÖÆ£¡ PMC-S963ϵÁÐÖ§³Ö6ÖÖ·ÑÂÊÓÅ»¯Óõç¹ÜÀí
  4. ¹©Åäµçϵͳ¹ÊÕÏÕï¶ÏÓëµçÆøÉ豸½¡¿µÔ¤²â£¬ÊµÏÖÉ豸Òþ»¼¡°Î´²·ÏÈÖª¡±
  5. ÐéÄâµç³§ÈçºÎʵÏÖÔ´ºÉ»¥¶¯£¿
  6. °²¿ÆÈð·Ö²¼Ê½¹â·ü¼à¿ØÏµÍ³ÔÚ¹ãÎ÷´óÌÆÖÁÆÖ±±¸ßËÙ¸ßËÙ£¨ÆÖ±±»¥Í¨£©ÏîÄ¿ÖÐÓ¦ÓÃ
  1. Îݶ¥±äÉí¡°·¢µçÕ¾¡± £¬CETÖе缼ÊõÖúÁ¦ÖÐÌìºÏ´´ÎÝÃæ·Ö²¼Ê½¹â·ü·¢µçÏîĿ˳Àû²¢Íø
  2. Òò·Ö²¼Ê½¹â·ü½ÓÈëµ¼ÖÂÅ©´åÌ¨ÇøµçѹԽÏÞ£¬CETÖе缼ÊõÈçºÎ½â¾ö£¿
  3. ¡¾CETÖе缼Êõ¡¿´óÐ͹¤ÉÌÒµ·Ö²¼Ê½¹â·üÈçºÎÅäÖ÷ÀÄæÁ÷·½°¸?
  4. ÈçºÎ½â¾ö³ÇÊйìµÀ½»Í¨µçÆø»ðÔÖ¼à¿ØÏµÍ³Î󱍯µ·¢£¿
  5. ÖÇÄܵç±íÖеķ塢¼â¡¢Æ½¡¢¹ÈÊÇʲôÒâ˼£¿ÔõôËãµç·Ñ£¿
  6. »¯¹¤ÆóÒµµÍѹµç¶¯»úÈçºÎ·À¡°»Îµç¡±£¿ÉîÛÚÖе翹»Îµç×°Öýâ¾ö·½°¸
  7. ½­Î÷ÍêÉÆ·Öʱµç¼Û»úÖÆ£¡ PMC-S963ϵÁÐÖ§³Ö6ÖÖ·ÑÂÊÓÅ»¯Óõç¹ÜÀí
  8. ¹©Åäµçϵͳ¹ÊÕÏÕï¶ÏÓëµçÆøÉ豸½¡¿µÔ¤²â£¬ÊµÏÖÉ豸Òþ»¼¡°Î´²·ÏÈÖª¡±
  9. ÐéÄâµç³§ÈçºÎʵÏÖÔ´ºÉ»¥¶¯£¿
  10. °²¿ÆÈð·Ö²¼Ê½¹â·ü¼à¿ØÏµÍ³ÔÚ¹ãÎ÷´óÌÆÖÁÆÖ±±¸ßËÙ¸ßËÙ£¨ÆÖ±±»¥Í¨£©ÏîÄ¿ÖÐÓ¦ÓÃ
ÈȴʼìË÷£ºABCDEFGHIJKLMNOPQRSTUVWXYZ

¹Ø±Õ